PROBLEM 2 - BREW VOLUME OR BREWS CONTINUOUSLYTOO MUCH
page5of8
BLOOMFIELD 1016BVM TROUBLESHOOTING GUIDE
BREW TIME & VOLUME (continued)
IF
IF
IF
IF
IF
IF
WATER TEMP
(ºF)
OFF
185
190
195
200
205
10
20
30
40 50
60
70
80
SOLENOID TIMER
(WATER VOLUME)
(SECONDS)
BREW SIGNAL TIMER:
- BREW LIGHT
END OF BREW BEEPER
(MINUTES)
2
3
4
5
6
7
8
Tank temperature must not exceed local boiling temperature. Set
no higher than local boiling temperature (based on altitude) minus 5ºF.
water is boiling in tank, Remove 2” silver hole plug from brewer body lower
water temp setting.
Brewer must be installed on a water line with pressure of no more than 90 PSI.
If water pressure exceeds 90 PSI at anytime, a pressure regulator must be
installed in water supply line to limit pressure to less than 90 PSI.
Remove 2” silver hole plug from brewer body. Inlet solenoid
open time is controlled by upper dial on control board. Be
sure pointer on dial is set to desired time in seconds.
may
brew time cannot be adjusted, or timing is outside of
useable range, replace control board p/n 83635.
Using a reliable stopwatch, measure actual brew time and
compare to time on dial. Set dripout time (lower right dial on
controller) to minimum. Press BREW key. BREW indicator will
glow and relay on power board will click. At end of brew cycle, three beeps
sound and BREW indicator goes out.
Silicone hose from inlet valve be removed from tank fitting and directed to an
empty decanter to verify volume. All flow from hose must stop at end of brew
cycle.
brew time of 120 seconds is too long, move volume
control jumper to cover both pins. This will reduce
timing range to 60 - 180 seconds.
brew time is acceptable, but flow continues or hose
continues to drip, replace inlet solenoid p/n 85752.
PROBLEM 3 - BREW LIGHT REMAINS LIT FOR TOO LONG PAST END OF BREW
Remove 2” silver hole plug from brewer body.
Brew signal time (dripout) is added to end of brew cycle.
This is to allow time for water remaining in brew chamber
to drip out as coffee before a new brew is initiated.
Be sure pointer on dial is set to desired time in minutes.
dripout timer cannot be set, replace controller p/n 83635.
WATER TEMP
(ºF)
OFF
185
190
195
200
205
10
20
30
40 50
60
70
80
SOLENOID TIMER
(WATER VOLUME)
(SECONDS)
BREW SIGNAL TIMER:
- BREW LIGHT
END OF BREW BEEPER
(MINUTES)
2
3
4
5
6
7
8
1
VOLUME
CONTROL
JUMPER
NOTE: Time cannot be adjusted during a brew cycle.
Service Bulletin 107.002
7 of 10