PROBLEM 1 - MAIN WARMER DOES NOT HEAT
page8of8
BLOOMFIELD 1016BVM TROUBLESHOOTING GUIDE
WARMER PLATES
CAUTION
The following procedure exposes live electric circuits.
Use due care when working around electricity.
Remove front panel. C
Fuse is located in lower right corner
of power board bracket. Remove fuse and check for continuity. If fuse is bad
(no continuity/infinite ohms), examine wiring and element for obvious
damage. Locate and repair cause of short before replacing fuse p/n 83164.
fuse is OK (continuity/zero ohms), replace warmer element
p/n 8572-18.
voltage is NOT present and warmer light is lit, be sure wiring and connectors are
in good condition, then replace power board p/n 83656.
heck for voltage between power board terminal WPLATE1
and terminal block L2 (white wire).
voltage is present, check warmer plate fuse.
warmer
voltage is present and
IF
IF
IF
Main warmer plate will energize automatically at start of a brew. Plate may also
be energized by pressing LOWER WARMER key. LED above LOWER key will
glow when warmer plate is energized.
Service Bulletin 107.002