Bloomfield 1016BVM Anleitung zur Fehlerbehebung

Stöbern Sie online oder laden Sie Anleitung zur Fehlerbehebung nach Kaffeemacher Bloomfield 1016BVM herunter. Bloomfield 1016BVM Troubleshooting guide Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 10
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
WELLS BLOOMFIELD, LLC
SERVICE BULLETIN
2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439
telephone: 775-689-5707
fax: 775-689-5976
www.wellsbloomfield.com
607.002
TO: Bloomfield Authorized Service Agencies June 26, 2007
FROM: Tony Nixon, National Service Manager
SUBJECT: Troubleshooting 1016BVM
Model 1016BVM brewers utilize electronic control boards for timing and
power switching functions. While it is tempting to immediately replace
these electronic components in the case of equipment malfunction, they
are, in fact, generally quite reliable and are seldom the root cause of the
problem. Learning the unique characteristics of these controllers will help
the service technician diagnose problems and return units to service more
efficiently.
We have recently experienced a high number of warranty claims where
the probe and both boards have been replaced. It is highly unlikely that
all three parts would fail simultaneously. Tests of returned boards and
probes show a very high percentage to be non-defective.
This brewer incorporates several features that render strictly intuitive
troubleshooting ineffective:
Unit is equipped with a high wattage heating element coupled with
programmed action to insure rapid temperature recovery. The heater
is energized near the start of a brew cycle and remains energized until
the water inlet solenoid is de-energized. Water supply volume and
pressure during the brew are critical. Insufficient water volume during
a brew will allow the heater to boil available water, causing the unit to
overheat. Symptoms include very little water dispensed during a
brew, a general fault (all lights flashing) and/or tripped hi-limit safety.
With traditional mechanical thermostats it is common procedure to
adjust settings during a brew. This is not possible with this control
board. Programming examines water temperature when it receives
a brew signal, and brew cannot start until water is at the setpoint
temperature. So that a brew is not interrupted by the influx of cold
water, once a brew is initiated, programming does not look at tank
temperature again until brew is completed. Neither setpoint, brew
time nor dripout time may be adjusted during a brew.
Attached is a comprehensive troubleshooting guide for your use in
diagnosing problems with this brewer. We fully expect that use of this
guide will eliminate unnecessary replacement of good parts, as well as
improving technician knowledge of, and comfort level with, this equipment.
IMPORTANT SERVICE
INFORMATION
Control boards, power boards
and temperature probes
submitted for warranty will be
tested.
Any board found not to be
defective will be returned to
you.
Warranty costs, including
labor and associated
expenses, will NOT be
credited for replacing
non-defective items.
SvcB 607.002 Rev. B 080313 cps
1 of 10
Seitenansicht 0
1 2 3 4 5 6 7 8 9 10

Inhaltsverzeichnis

Seite 1 - 607.002

WELLS BLOOMFIELD, LLCSERVICE BULLETIN2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439telephone: 775-689-5707fax: 775-689-5976www.wellsbloomfield.com607.00

Seite 2 - 2 of 10

PROBLEM 1 - MAIN WARMER DOES NOT HEATpage8of8BLOOMFIELD 1016BVM TROUBLESHOOTING GUIDEWARMER PLATESCAUTIONThe following procedure exposes live electric

Seite 3 - 3 of 10

BLOOMFIELD 1016BVM WIRING DIAGRAM L2NGL1VOLTS PHASE WATTS120/240 1 3800ref. dwg# 736413-WARMERAUTOMATIC BREWERMODEL 1016BVMNEUTRAL INVALVE BHEATER BVA

Seite 4 - 4 of 10

BLOOMFIELD 1016BVM TROUBLESHOOTING GUIDESCOPE: This Troubleshooting Guide addresses potential problems peculiar to this specificbrewer. Normal mainten

Seite 5 - 5 of 10

All LEDs flashing: GENERAL FAULTPossible causes are a shorted temperature probe, an over-temperature condition,or controller did not detect at least 2

Seite 6 - 6 of 10

page3of8BLOOMFIELD 1016BVM TROUBLESHOOTING GUIDEDIAGNOSTICS - FLASHING LIGHTS AND BEEPING ALERTSTEST FOR NORMAL OPERATION ON INITIAL START-UPWhen powe

Seite 7 - 7 of 10

PROBLEM 1 - BREW VOLUME (SHORT POT)TOO LITTLEpage4of8BLOOMFIELD 1016BVM TROUBLESHOOTING GUIDEBREW TIME & VOLUMEIFIFIFWATER TEMP(ºF)OFF185190195200

Seite 8 - 8 of 10

PROBLEM 2 - BREW VOLUME OR BREWS CONTINUOUSLYTOO MUCHpage5of8BLOOMFIELD 1016BVM TROUBLESHOOTING GUIDEBREW TIME & VOLUME (continued)IFIFIFIFIFIFWAT

Seite 9 - 9 of 10

WATER TEMPERATUREPROBLEM 1 - WATER TEMPERATURE WILL NOT CONTROLTEMPERATURE TOO LOW OR NO HEATRemove 2” silver hole plug from brewer body.Water tempera

Seite 10 - 10 of 10

PROBLEM 2 - WATER TEMPERATURE WILL NOT CONTROLTEMPERATURE TOO HIGH OR RUNAWAYRemove 2” silver hole plug from brewer body.Water temperature setpoint is

Kommentare zu diesen Handbüchern