PROGRAMMING - PROCEDURES (continued)
Service & Counters
Machine Settings
Below are the boiling points for
selected North American loca-
tions, and the recommended
Maximum Water Temperature
settings for the E-Max™:
· “TotalVol:” – Total Volume. Indicates total water volume
processed by the brewer.
· “Brew Cycs:” – Brew Cycles. Displays total number of
brew cycles since last reset.
· “FltrLife:” – Filter Life. If a filter is used input the number of
gallons of capacity, the indicator reports in increments of 100
gallons.
· “Reset Totals:”. To clear out totals for volume and brew
cycles.
· “Srv” – Service Number. Displays the service phone that
will display when a diagnostic message is on the LCD. Can
only be loaded with the PC upload/download program.
· “Temp. Unit:” – Temperature Unit. Set to “F” for ºF and
“C” for ºC.
· “Vol. Unit:” – Volume Unit. Set to either “oz” for ounces or
“L” for liters. (For Tea Brewers this is set to gallons.)
· “KeyPadLock:” Turn to “On” or “Off”. If “On” the keypad
switches can only be activated by pressing and holding the
CANCEL key for 6 seconds. Then the keypad will be active
until a brew has been completed. Or if a brew is not started
the keypad will revert to the locked mode after 60 seconds.
· “MaxWt.Temp:” – Maximum Water Temperature. The
maximum water temperature is factory set at 208ºF degrees,
but can be adjusted up as high as 210ºF. The brew
temperature cannot be set any closer than 5º below the
maximum temperature. Maximum temperature should be set
at least 2ºF degrees below the boiling point. The E-Max™
will go into the “overheat error” if the water temperature in the
tank is sensed to be at or above the Maximum Water
Temperature level. Therefore in higher altitude locations,
adjust the Maximum Water Temperature down.
See temperature charts, page 15.
· “Mode:” – Operating Mode. Set this to operate as “Decanter”
or “Thermal”.
In “Decanter” mode, the 3 keys on the right operate as
warmer plate switches.
In “Thermal” the 3 keys on the right operate as volume
selection switches.
Tea Brewers are pre-set to tea brewer mode.