SERVICING INSTRUCTIONS (continued)
TEMPERATURE ADJUSTMENT
Place empty decanter under brew chamber. Energize brewer
and allow unit to heat. When HEAT light goes out, press
BREW key. Use a temperature probe with needle tip to read
temperature of water stream as it exits brew chamber.
Adjust WATER TEMP dial on controller; clockwise increases
temperature. Refer to Table 1 below for proper brewing
temperature based on altitude.
Fig. 13 Checking and Adjusting Brew Temperature
CAUTION
BURN HAZARD
Brew water is extremely
hot and can cause burns
on contact. Hold probe with
tip pointing down to avoid
contacting hot water.
IMPORTANT:
Temperature setpoint cannot be
changed during a brew. New
settings will not be effective until
end of brew.
NOTE: Optimum brewing
temperature is 200ºF (93.3ºC)
± 5ºF (±2.8C).
Thermostat must be adjusted so
that tank temperature does not
exceed 205ºF (96ºC).
IMPORTANT:
An electronic temperature
controller will maintain
temperature within ±2ºF.
To prevent boiling water in
the brewer, controller should
be adjusted to a maximum
temperature equal to the local
boiling temperature minus 2ºF,
or 205ºF, whichever is less.
Table 1 Boiling Temperature by Altitude
15
912 p/n 2M-75936 Owners Manual 1016BVM Coffee Brewer