PRINTED IN UNITED STATES OF AMERICA 605 OWNERS MANUAL for INTEGRITY™ 5-WARMER COFFEE BREWERS MODEL: 8752 8752KFT Includes: Installation O
BREWING COFFEE CAUTION: BURN HAZARD Exposed surfaces of the brewer, brew chamber and decanter may be HOT to the touch, and can cause serious b
CLEANING INSTRUCTIONS PROCEDURE: Clean Coffee Brewer PRECAUTIONS: Disconnect brewer from electric power. Allow br
10 TROUBLESHOOTING SUGGESTIONS SUGGESTED REMEDY Check power supply cord Check / reset circuit breaker Set for desired temperature Allow to cool Res
SERVICING INSTRUCTIONS CAUTION: SHOCK HAZARD Opening access panels or removing warmer plates on this brew may expose uninsulated electrical compo
SERVICING INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT Unplug power cord or turn circuit breaker OFF. Remove top panel. Pull vent tube out of t
SERVICING INSTRUCTIONS (continued) 13 IMPORTANT: Water pressure must be between 20 p.s.i and 90 p.s.i. flowing pressure. If water pressure ex
SERVICING INSTRUCTIONS (continued) 14 REPLACE SOLENOID Symptom: Automatic brewer will not flow water; or, automatic brewer drips continuously from b
REPLACE TIMER ASSEMBLY Unplug power cord or turn circuit breaker OFF. Remove front panel. Remove knob and three screws holding timer to bracket. D
CAUTION: CHEMICAL BURN HAZARD Deliming chemicals may be caustic. Wear appropriate protective gloves and goggles during this procedure. Never sip
7. Set the tank back into the brewer. Reassemble the tank lid to the water tank. Make sure the gasket is properly in place, then re
NOTE: For your protection, please note that equipment in this shipment was carefully inspected and packaged by skilled personnel before leaving the f
EXPLODED VIEW & PARTS LIST 18 CABINET ASSEMBLY ITEM PART NUMBER DESCRIPTION 1 8700-16 PLATE, WARMER COVER 4 8543-80 CLIP, MOUNTING 23 BU
EXPLODED VIEW & PARTS LIST (continued) 19 ELECTRICAL COMPONENTS ITEM PART NUMBER DESCRIPTION 2 8572-18 ELEMENT, WARMER 120V 100W 30 8707-5
EXPLODED VIEW & PARTS LIST 20 HOT WATER TANK ASSEMBLY ITEM PART NUMBER DESCRIPTION 13 8043-5 HOLD-DOWN STRAP 14 8942-92 NUT 8-32 HEX KEPS 50
EXPLODED VIEW & PARTS LIST (continued) 21 PLUMBING COMPONENTS ITEM PART NUMBER DESCRIPTION 8 8540-3 ASSEMBLY, FORMED TUBE FAUCET SUPPLY 9 869
EXPLODED VIEW & PARTS LIST (continued) 22 SERVICE KITS FAUCET REPAIR KITS 82573 Handle (item 12a) 82575
WIRING DIAGRAM 23 605 70988 Owners Manual Integrity 5W Decanter Brewer
PRINTED IN UNITED STATES OF AMERICA Bloomfield Industries, Inc.Division of Carrier Commercial RefrigerationIn US and CanadaTelephone: 775-689-5700Fax:
MODEL STYLE VOLTS WATTS AMPS 1ø POWER SUPPLY CORD 8752 8752KFT Decanter Brewer 5 Warmers 115/230 4000 19.4 None provided Wire directly to circuit
FEATURES AND OPERATING CONTROLS 2 Fig. 1 Model 8752 Features and Operating Controls 605 70988 Owners Manual Integrity 5W Decanter Brewer
PRECAUTIONS AND GENERAL INFORMATION 3 WARNING: ELECTRIC SHOCK HAZARD All servicing requiring access to non-insulated components must be performed by
INSTALLATION 4 READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION REFER TO EXPLODED VIEWS FOR COMPONENT NAMES/NUMBERS Unpack the unit. Inspect all
INSTALLATION (continued) 5 NOTE: This equipment must be installed to comply with applicable federal, state and local plumbing codes and
OPERATION Fig. 4 Brewer Operation Diagram START-UP For initial start-up, or if the brewer has not been used for an extended pe
OPERATION (continued) Water temperature is sensed by a thermobulb inserted into the water tank. This temperature signal is fed to the ther